Copper Clad Steel CCS Wire 0.1mm to 5.19mm for Electrical Grounding Applications
|
Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Certification: | ISO, CCC, CE |
| Surface: | Smooth |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Find Similar Products
Basic Info.
- Model NO.
- 0.1-5.19mm
- Technique
- Galvanized
- Application
- Rope, Packaging, Netting, Manufacturing, Fencing, Construction, Steel Cable
- Alloy or Not
- Non-alloy
- Standard
- BS, JIS, GB, ASTM, DIN, AISI
- Samples
- Free Samples
- MOQ
- 1 Ton
- Transport Package
- Coil Packing, Z2 Packing, Wooden Reel Packing
- Specification
- 0.1-5.19mm
- Trademark
- Yunhe
- Origin
- China
- HS Code
- 7217100000
- Production Capacity
- 12000 Ton Per Month
Product Description
Copper Clad Steel CCS Wire 0.1mm to 5.19mm for Electrical Grounding Applications
CCS wire is formed through electroplating method (taking steel wire as the core and depositing the copper layer evenly on the surface of the steel core) and cladding method (Cladding planished copper stripe concentrically on the outer surface of the steel core).|
Wire material |
Copper Clad Steel(CCS) |
|
Standards |
ASTM B452, ASTM B227,ASTM B869,ASTM B910/B910M,BS4087,ST11411 |
|
Wire diameter |
16~300 mm² |
|
Tensile strength |
290 Mpa - 1500 Mpa(N/mm²) |
|
Electrical conductivity |
21%-30%-40% |
|
Elongation |
1%-25% |
|
Life |
≥30years |
|
Certificate |
ISO9001:2015 |
Copper clad steel wire (CCS) combines the high tensile strength of steel as its core and the conductivity properties of copper as its outer layer. The core material is usually low carbon steel and is typically used as either grounding wire or the inner conductor of coaxial cables. Copper clad steel is made to ASTM B-452 standards with 40% conductivity in two tempers: soft and hard drawn.
The resistivity and density and min copper thickness of copper clad stell wire
| Type | Max resistivity at 20ºC | Density at 20ºC | Main copper thickness% mm |
| 21A,21HS | 0.08210 | 7.98 | 1.5 |
| 30A,30HS,30EHS | 0.058616 | 8.15 | 3 |
| 40A,30HS,30EHS | 0.043970 | 8.24 | 5.0 |
| 70A | 0.026524 | 8.58 | 15.0 |
Advantage
1.The copper clad steel wire by cladding in no pollution.
2.High tensile strength:this kind of wire is suitable for overhead transmission lines.
3.Light weight:The length of the copper clad steel wire is bigger than the pure copper wire for the same specification.
Application:
Telephone wire CATV cable
electrical power communication overhead wire
High temperature conductor Intemet cable
Comouter cable Electronics contact fittings Shielded line of electric power cable
Min Copper thickness of copper clad steel wire
| Type | Min Copper Thickness% mm |
| 21A, 21HS | 1.5 |
| 30A, 30HS, 30EHS | 3 |
| 40A, 30HS, 30EHS | 5.0 |
| 70A | 15.0 |
(ASTM) Standard:
21, 21hs----Annealed, High Strength, 21% Conductivity 30A, 30HS, 30EHS--------------Annealed, High and Extra High Strength, 30% Conductivity 404, 40HS, 40EHS------------Annealed, High and Extra High Strength, 40% Conductivity 70A---------Annealed, 70% Conductivity
The Range of Product
CCS made by clad-welding method, the range of CCS we can produce is 0.05-5.2mm, and we can also produce as customer's requirements.
Requirements for Tensile Strength And Elongation of copper clad steel wire for Electronic products
| Dia mm | Sectional Area mm2 | Tensile Strength Mpa | (250mm) Min Elogation Lo =250mm |
||||
| 30HS | 30A | 40HS | 40A | 30HS, 40HS | 30A, 40A | ||
| 1.83 | 2.63 | 875 | 345 | 758 | 310 | 1.5 | 15 |
| 1.63 | 2.08 | 875 | 345 | 758 | 310 | 1.5 | 15 |
| 1.45 | 1.65 | 875 | 345 | 758 | 310 | 1.5 | 15 |
| 1.29 | 1.31 | 875 | 345 | 758 | 310 | 1.5 | 15 |
| 1.15 | 1.04 | 875 | 345 | 758 | 310 | 1.5 | 15 |
| 1.02 | 0.823 | 875 | 345 | 758 | 310 | 1.0 | 15 |
| 0.912 | 0.653 | 875 | 345 | 758 | 310 | 1.0 | 15 |
| 0.813 | 0.519 | 875 | 345 | 758 | 310 | 1.0 | 15 |
| 0.724 | 0.412 | 875 | 380 | 758 | 345 | 1.0 | 15 |
| 0.643 | 0.324 | 875 | 380 | 758 | 345 | 1.0 | 15 |
| 0.574 | 0.259 | 875 | 380 | 758 | 345 | 1.0 | 15 |
| 0.511 | 0.205 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.455 | 0.162 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.404 | 0.128 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| Dia mm | Sectional Area mm2 | Tensile Strength Mpa | (250mm) Min Elogation Lo =250mm |
||||
| 30HS | 30A | 40HS | 40A | 30HS, 40HS | 30A, 40A | ||
| 0.361 | 0.102 | 875 | 380 | 758 | 310 | 1.0 | 10 |
| 0.320 | 0.0804 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.287 | 0.0647 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.254 | 0.0507 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.226 | 0.0401 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.203 | 0.0324 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.180 | 0.0255 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.160 | 0.0201 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.142 | 0.159 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.127 | 0.0127 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.144 | 0.0103 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.102 | 0.00811 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.089 | 0.00621 | 875 | 380 | 758 | 345 | 1.0 | 10 |
| 0.079 | 0.00487 | 875 | 380 | 758 | 345 | 1.0 | 10 |
Tensile Strength And Resistance of Hardness Copper Clad Steel Wire
ASTM B227
Dia mm |
Sectional Area mm2 |
Tensile Strength Mpa |
Max D.C.Resistance At 20ºC /Km |
||||
| 40HS | 40EHS | 30HS | 30EHS | 40HS, 40EHS | 30HS, 30EHS | ||
| 5.189 | 21.15 | 745 | 1076 |
828 | 983 | 2.1431 | 2.8568 |
| 4.620 | 16.77 | 780 | 863 | 1038 | 2.7032 | 3.6025 | |
| 4.191 | 13.79 | 814 | 897 | 1088 | 3.2843 | 4.3801 | |
| 4.155 | 13.30 | 814 | 897 | 1088 | 3.4057 | 4.5442 | |
| 3.665 | 10.55 | 849 | 932 | 1132 | 4.2948 | 5.7253 | |
| 3.264 | 8.37 | 883 | 966 | 1173 | 5.4169 | 7.2215 | |
| 3.251 | 8.30 | 833 | 966 | 1173 | 5.4596 | 7.2773 | |
| 2.906 | 6.63 | 918 | 1001 | 1173 | 6.8343 | 9.1113 | |
| 2.624 | 5.48 | 956 | 1042 | 1201 | 8.2714 | 11.0242 | |
| 2.588 | 5.26 | 956 | 1042 | 1208 | 8.6126 | 11.4835 | |
| 2.052 | 3.31 | 956 | 1042 | 1235 | 13.7999 | 18.3966 | |
| 2.032 | 3.24 | 956 | 1042 | 1235 | 14.0821 | 18.7739 | |
| 1.626 | 2.08 | 956 | 1042 | 1235 | 22.2157 | 29.6176 | |
| 1.024 | 0.823 | 956 | 1042 | 1235 | 56.2035 | 174.9052 | |
| 0.991 | 0.771 | 956 | 1042 | 1235 | 60.1079 | 80.1220 | |
| 0.813 | 0.519 | 956 | 1042 | 1235 | 90.2931 | 120.3799 | |
CATV Applied in CATV
ASTM B869
Nominal Dia |
Tolerance |
Sectional Area |
Max D.C. Resistance At 20ºC |
Breaking Load |
Weight |
| mm | Mm | mm2 | /Km | N | KG/Km |
| 1.628 | 0.015 | 2.082 | 40.1890 | 1722 | 16.52 |
| 1.450 | 0.015 | 1.652 | 50.7636 | 1366 | 13.47 |
| 1.290 | 0.013 | 1.307 | 64.0484 | 1081 | 10.40 |
| 1.151 | 0.013 | 1.039 | 80.7388 | 859 | 8.27 |
| 1.024 | 0.010 | 0.823 | 101.7897 | 681 | 6.71 |
| 0.813 | 0.008 | 0.519 | 161.2612 | 427 | 4.12 |
| 0.724 | 0.008 | 0.411 | 203.7731 | 334 | 3.35 |
Package photo:
Copper clad steel wires package can be plastic reels, polywood drums, coils, etc. Can pack as per customer request.